MFOS 1V Per Octave Calibrator

MFOS 1V Per Octave Calibrator

$15.00

From MFOS - A 1V per octave calibrator PCB!

This is for a PCB only, suitable for multiple formats.
- +
Availability:In stock
  • This is an intermediate to advanced project and I do not recommend it as a first project if you are just getting started in synths or electronics. Only the circuit and some explanation are shown here. A lot of project building, troubleshooting and electronics experience is assumed. Additionally, electronic equipment ownership (scope, meters, etc.) is taken for granted. If you are interested in building this project please read the entire page before ordering PC boards to ensure that the information provided is thorough enough for you to complete the project successfully.

 

Features

  • Variable Cycle Rate
  • 0V thru 3V and 0V thru 7V settings
  • Very accurate when resistors are hand selected to 0.1%
  • Facilitates calibration of Volt Per Octave modules.

Introduction

This is the volt per octave calibrator I developed to make calibrating VCOs and VCFs easier. I used this in the "MFOS VCO Calibration Part I" and "MFOS VCO Calibration Part II" YouTubes. It is way easier than constantly resetting a regular power supply and way cheaper than a programmable power supply.

 

 
MFOS VCO Calibration Part I

MFOS VCO Calibration Part II

The circuit is fairly simple but does the job of providing a nice accurate 0 thru 7 volt source that steps by 1V increments. With careful selection of the resistors used in the R/2R ladder (R3,R4,R6,R7,R8,R9) you can get 0.1% accuracy.

The circuit is powered by a simple zener supply so that the voltages used in the 1V stepping circuit don't depend too heavily on the supply voltage (+12V and -12V or +15V and -15V). You should be powering this from a stable source of voltage like your synth's supply or your bench supply. I ran the +V, -V, and Ground supply wires to alligator clips so I can just piggy back on whatever voltage I am feeding into whatever I am calibrating. Recalibrate the circuit any time you switch supplies. For example any time you go from +/-12V to +/-15V or +/-15V to +/-12V.

We use a CD40106 (hex inverting schmitt trigger) to supply a free running clock source and a manual step clock source. U1-A,B, and C are used in the free running clock source. U1-A and R11, R12 and C5 comprise a square wave oscillator that goes from ground to 9VZ. U1-A's output is always reaching around to it's input and causing it to change state. With U1-A's output low C5 discharges (via R11 and R12) until it is below U1-A's lower trip point at which time U1-A's output goes high and then when C5 charges (via R11 and R12) to above U1-A's upper trip point U1-A's output goes low and the cycles continue to repeat. R12 in series with R11 (1 meg linear pot) supply rate control as they determine how fast or slow C5 charges and discharges. U1-B in conjunction with U1-C buffer U1-A's output. The high going excursions of U1-C's output forward bias D1 and drop 9VZ (minus a negligible diode drop) on R20. When the Cycle On/Off switch (S2) is open the square waves dropped on R20 are applied to the CLK input of counter A in the CD4520 Dual Binary Counter and it counts from 0 to 3 or 0 to 7 depending on the setting of S1. When the Cycle On/Off switch (S2) is closed 9VZ is applied to pin 1 of U1-A which stops the oscillation and causes U1-C to go to a low state. In this condition no clock pulses are applied to the CLK input of counter A in the CD4520 Dual Binary Counter and it is incremented by the manual step control only.

U1-F, E, and D comprise the manual clock source. We use the hysteresis of the CD40106 to debounce the pushbutton. Normally with S3 open 9VZ through R18 charges C9 and hold U1-F and subsequenctly U1-D's output low. When S3 is pressed C9 is discharged via R19 to about ground causing U1-F and subsequenctly U1-D's output to go high providing a clock signal via D2 to be applied to U2's counter A CLK input. When the button is released C9 charges up again and U1-F's output goes low. The low pass filtering provided by the RC networks of R18/C9 and R19/C9 keep the switch chatter from causing multiple clocks to be emitted.

S1 controls the maximum count U2 attains before resetting. With S1 closed the counter resets when Q3A goes high (count of 4) since the 4 count resets the counter it never gets to 4 but cycles 0 thru 3. With S1 open the counter cycles 0 through 7 repeatedly.

Q1A, Q2A, and Q3A feed the R/2R network. As the counter counts from 0 through n the voltage picked off of the R/2R network steps up in equal increments. It is VERY IMPORTANT TO SELECT R3,R4,R6,R7,R8, and R9 to within +/-0.1% of the target values. You don't have to be exactly 100K and 200K you just need the R to 2R ratio to be consistent between them all. For example lets say you measure several resistors from the 100K 1% metal film batch you have and find two at 99.50K +/-0.1%. Set these aside and now as you go through the 200K batch you must look for 4 pieces that are 199.00K +/-0.1%. You see... the ratio of the values is important not the actual values. However do not think "Hey, I've got some 1K and 2K I can use..." We use 100K and 200K so as not to load the outputs of the CD4520 to make sure that the R/2R network gets nice pure 9VZ levels.

U3 buffers the output of the R/2R ladder and supplies the buffered voltage to U4 via level trim network R5, R10 (trimmer), and R13. U4 then buffers the trimmed voltage and drives the output via J1.

C2 and C8 clean up the power coming into the board and C3,C4,C6, and C7 are used to bypass the power supply close to the op amp power pins.

Calibration We are going to measure the outputs of U3 and U4 to make sure they are "nulled" i.e. their outputs are as close to 0V as possible. Ensure that counter U2 is at step zero (Q1, Q2, and Q3 all low). As you observe the voltage on the output of U3 (pin 6) adjust trimmer R16 until you read as close to 0V as possible. As you get closer to 0V adjust your meter's range down to 200mV (or better) to get greatest precision as you get to the target 0V. Do the same for U4 using trimmer R14. Now ensure counter U2 is at step 7 (Q1, Q2, and Q3 all high). As you observe the output of U4 (pin 6) adjust trimmer R10 until you read as close to 7.000 volts as possible at the output of U4. You should now see that the steps are very close to 0,1,2,3,4,5,6 and 7 volts with high (+/-0.1%) accuracy.

Changing Cycle Rate Range If you would like to slow the cycle rate range you can increase the value of C5. You can use ceramic caps or non-polarized aluminum caps or even aluminum or tantalum polarized caps but if you use a polarized cap make sure you put the negative side of the cap to ground. The ground side of the cap is the donut that also connects to U1 pin 7. I suggest keeping the value below 2uF but that's just a suggestion (larger values won't hurt anything).

 

 

 

Approx. Current Consumption
+12V 15mA
-12V 15mA